Award for innovative cell culture technology

Researchers at ETH Zurich have developed a new cell culture method, which may very well enable to forgo certain tests on animals in the future. The scientists were awarded an international prize for more humane treatment of laboratory animals.

Mikrotiterplatte
Close-up of a microwell plate for microtissue spheroid culturing according to the new method recently developed by ETH scientists. (Photograph: ETH Zurich / Olivier Frey)

A team headed by scientists from the Department of Biosystems at ETH Zurich in Basel has developed a cell culture technology platform for testing interactions between chemical and pharmaceutical compounds and three-dimensional body tissue samples. While conventional cell culture experiments are performed using a two-dimensional cell layer in a petri dish, the new technology relies on a chip that accommodates small three-dimensional tissue spheroids that are barely half a millimetre in diameter.

“The three-dimensional microtissues better mimic organ tissue behaviour in a living body in comparison to conventional cell cultures and thus provide more meaningful results,” says Olivier Frey, who is senior assistant in ETH Professor Andreas Hierlemann’s lab and was largely responsible for developing the new method. Another unique feature of the new technology is that scientists are able to combine spheroids made from different tissues in one chip so that they can easily test compound interactions and impact on various tissue types.

More complex experiments now possible

More specifically, the new technology will allow scientists to test the efficacy of compounds to see, for example, whether a potential cancer drug inhibits the growth of tumour cells. By combining tumour and liver tissue in a single chip, researchers are additionally able to test whether the hepatic metabolism decreases or enhances the activity of the active agent, and whether the respective agent is toxic to the liver. In addition to testing drug candidates, it may also be possible to use the newly developed technology in personalised medicine.

In addition to combining cancer and liver tissues, which scientists have tested in their proof-of-concept study, other tissue combinations are conceivable. Researchers are now planning to work on a system including microtissues of organs affected by diabetes: pancreas and liver.

Prize for reducing animal experiments

In contrast to conventional cell culture experiments, the microtissue-based method is useful for providing more comprehensive answers to complex biomedical questions, many of which required animal experiments up to now. The technology offers the potential to reduce the number of animal experiments in biomedical research.

On 2 November, an international panel of experts  therefore awarded the consortium around the  ETH scientists the Global 3Rs Award/Europe, an international prize for research efforts to reduce animal experiments (see box). This is the second prize of this type that goes to the research group; in 2014 the group received an award from the UK-based National Centre for the Replacement, Refinement & Reduction of Animals in Research for an alternative system.

The body on a chip

The new technology was developed as part of an EU research project called “Body on a Chip”, which was coordinated by the ETH spinoff Insphero and which involved other European project partners. The name “Body on a Chip” alludes to the term “Lab on a Chip”, which describes miniaturised laboratory analysis platforms.

Chip
Model of the original chip used by scientists to carry out two experiments simultaneously: reservoirs on the left and right for nutrient medium, four wells for accommodating tissue spheroids in between. (Visualisations: ETH Zurich / Olivier Frey)
Mikrotiterplatten
Newly developed microwell plates on a tilting stage with motor (right) . The researchers can simultaneously carry out ten experiments on one of the microwell plates. (Photograph: ETH Zurich / Olivier Frey)

The main features of the cell culture chips developed by the ETH scientists include four (or six in the latest chip generation) wells in which tissue spheroids are placed and two reservoirs for the nutrient medium. A microchannel connects all wells and the reservoirs. Rocking or tilting motions of the chip or well plate slightly move the tissue spheroids and enable continuous perfusion and supply of nutrients and dosage of compounds.

The new technology is currently being used in a project supported by the Swiss Federation’s Commission for Technology and Innovation (CTI) in collaboration with Insphero and the pharmaceutical company Roche. “If this test phase in industry is successful, it will be possible to think about marketing the device,” says ETH professor Hierlemann.

Olivier Frey an der Preisverleihung des Global 3Rs Awards
Olivier Frey (3rd from left) at the Global 3Rs Award ceremony. (Photograph: AAALAC International)

The 3R principles

Efforts towards a more humane, ethical handling of laboratory animals are often subsumed under the term “3R”. The three Rs stand for “replacement” (replacing animal testing with experiments that do not require animals), “reduction” (reducing the number of animals that are used for testing) and “refinement” (limiting the impact on the animals during a trial along with better experimental planning). More and more organisations on the national and international level are stepping forward to support these principles, including the Association for Assessment and Accreditation of Laboratory Animal Care International (external page AAALAC International), which confers the external page Global 3Rs Awards in cooperation with the International Consortium for Innovation and Quality (external page IQ) in Pharmaceutical Development.

Reference

Kim JY, Fluri DA, Marchan R, Boonen K, Mohanty S, Singh P, Hammad S, Landuyt B, Hengstler JG, Kelm JM, Hierlemann A, Frey O: 3D spherical microtissues and microfluidic technology for multi-tissue experiments and analysis. Journal of Biotechnology 2015. 205: 24-35, doi: external page 10.1016/j.jbiotec.2015.01.003

JavaScript has been disabled in your browser